CHEMKIN models fail in FLUENT R13.0 when run in parallel on Windows 7. Some linux versions may also be affected.

Errors such as these may occur:

OMP: Error #15: Initializing libiomp5md.dll, but found libguide40.dll already initialized.
OMP: Error #15: Initializing libiomp5md.dll, but found libguide40.dll already initialized.
OMP: Hint: This may cause performance degradation and correctness issues. Set environment variable KMP_DUPLICATE_LIB_OK=TRUE to ignore this problem and force the program to continue anyway. Please note that the use of KMP_DUPLICATE_LIB_OK is unsupported
and using it may cause undefined behavior. For more information, please see http://www.intel.com/software/products/support/.
OMP: Hint: This may cause performance degradation and correctness issues. Set environment variable KMP_DUPLICATE_LIB_OK=TRUE to ignore this problem and force the program to continue anyway. Please note that the use of KMP_DUPLICATE_LIB_OK is unsupported
and using it may cause undefined behavior. For more information, please see http://www.intel.com/software/products/support/.

999999 (..srcmpsystem.c@1173): mpt_read: failed: errno = 10054

999999: mpt_read: error: read failed trying to read 4 bytes: No such file or directory
MPI Application rank 0 exited before MPI_Finalize() with status 3
The Parallel FLUENT process could not be started.


New CHEMKIN installers are available for FLUENT 13.0 that will resolve these problems.

Go to <a target=_blank href="http://reactiondesign.com/">http://reactiondesign.com/</a>http://reactiondesign.com/ - Support - CHEMKIN-CFD for FLUENT - Latest Release. This page explains which version of CHEMKIN-CFD is compatible with which version of FLUENT and provides links to the corrected libraries.

These problems are fixed in FLUENT R14.0.

See attached Resolution Document for more details.





Show Form