When calculating the covariance between two PSD quantities, should ANSYS be producing a value which is normalized? (i.e., 0 for no correlation and 1 for full correlation)


No, the covariance should not be confused with the coherence function or correlation coefficient. The covariance is output as defined in Equation 19-179 of the Theory Reference.

The attached file, K8-39s.dat, is a verification test of the CVAR functionality.





Show Form