I get the error below when starting the CFX-5 Solver:
+----------------------------------------------------------------------------+
| ERROR #001100279 has occurred in subroutine ErrAction. |
| Message: |
| No control surfaces have been found at all for Domain Interface 1- |
| . This is not supported. |
| |
+----------------------------------------------------------------------------+
+----------------------------------------------------------------------------+
| ERROR #001100279 has occurred in subroutine ErrAction. |
| Message: |
| Stopped in routine SU_MESH_GGI |
| |
+----------------------------------------------------------------------------+
This messager comes from a check that the CFX-5 Solver performs to see if the two sides of a GGI interface intersect. A common cause of this message is when the one side of a GGI periodic boundary does not map to the other side through the specified transformation. It can also occur when the two sides of a Domain Interface do not overlap. If it is intended for the two sides of a Domain Interface to not overlap (for example, in the transient rotor-stator analysis of a rotating valve) then you can set the expert parameter "ggi permit no intersection" to turn off this check. |
||
|