Is the default force convergence value adequate in electrostatic-structural MEMS simulations using the MFS?


In ANSYS, Release 10.0, the default convergence value of 1e-3 is often inadequate for the electrostatic force in electrostatic-structural MEMS simulations using the MFS. If the uMKS unit system is used, the convergence tolerance should be tightened. A convergence tolerance of 1e-5 is usually more appropriate. For other unit systems, other convergence values may be needed. The convergence value is specified using the MFCONV command.