Q. CFX appears to stop at the first opportunity saying a solver (or partitioner) "executable is required for this run, but none is available". The installation, however, appears to be correct.

A. It could be that you have a quite recent Opteron AMD64 machine and one of our programs is incorrectly identifying it as a K6. If this error is made, the solver tries to look for a different 32-bit executable, and hence does not find it within the 64-bit installation. This bug has been fixed in our Service Pack 1 for CFX-10. You can download it from the customer portal at http://www1.ansys.com/customer/ provided that you have the password.


Q. CFX appears to stop at the first opportunity saying a solver (or partitioner) "executable is required for this run, but none is available". The installation, however, appears to be correct.

A. It could be that you have a quite recent Opteron AMD64 machine and one of our programs is incorrectly identifying it as a K6. If this error is made, the solver tries to look for a different 32-bit executable, and hence does not find it within the 64-bit installation. This bug has been fixed in our Service Pack 1 for CFX-10. You can download it from the customer portal at <a target=_blank href="http://www1.ansys.com/customer/">http://www1.ansys.com/customer/</a>http://www1.ansys.com/customer/ provided that you have the password.





Show Form