Class 3 Error

SYMPTOM:
If the rgp files in etc/materials-extra are used for physical properties, incorrect results are obtained for heat transfer problems that are laminar or are turbulent with large regions of low eddy viscosity.

PROBLEM:
This is due to incorrect values of thermal conductivity being used in t


WORKAROUND:
Use the Redlich Kwong library material in place of the rgp file.

FIXED IN:
Release 11.0.