Class 3 Error

SYMPTOM:
The Liquid Evaporation Model can give incorrect answers if the user-specified latent heat option is used, without the Light Oil Modification, as the value will not be used. If the Automatic option is used for getting the latent heat, then there is no problem.

PROBLEM:
This is due to a bug in the CFX Solver in setting the actual latent heat to be used, which varies with


WORKAROUND:
The workaround is to set the reference enthalpies correctly in the material specification, and to then use the Automatic option.

FIXED IN:
Release 11.0. Custom executable for Release 10.0 available on request.