Class 3 Error

SYMPTOM:
In a MFX calculation, if the CFX initial time is less than the MFX initial time, CFX executes a sequence of multiple time steps during the first stagger iteration of a new simulation. These time steps begin at the CFX start time and stop at the end of the first MFX time step, and use only the first set of data/loads sent from ANSYS to CFX. Once CFX has reached the end of the first MFX time step for the first time, it is synchronized with ANSYS and they complete the required number of stagger iterations. Results generated by CFX before synchromisation are incorrect.

PROBLEM:
This is due to the CFX Solver not respecting the MFX initial time for all runs se


WORKAROUND:
There is no workaround.

FIXED IN:
Release 11.0.