We have installed CFX 11 on our IBM platform. CFX 10 works fine on this platform but CFX 11 gives the following message when we run the cfx5launch command:

cfx5launch
exec(): 0509-036 Cannot load program Launcher.exe because of the following errors:
rtld: 0712-001 Symbol _Getctype__FRCc was referenced
from the moodule Launcher.exe(), but a runtime definition
of the symbol was not found.
rtld: 0712-001 Symbol _Getcvt__FRCc was referenced
from module Launcher.exe(), but a runtime definition
of the symbol was not found.
rtld: 0712-002 fatal error: exiting.
An error has occurred in cfx5launch:

The CFX Launcher /install/ansys_inc/v110/CFX/bin/aix/Launcher.exe could not
be started, or exited with retrn code 255.

The IBM has AIX 5.3 installed on it which is supported by CFX 11. We have C++ Runtime Environment version 6 installed


The C++ runtime environment packages that you have installed are not a sufficient version. For CFX 11 you must have version 7.0 or later of the IBM C++ Runtime Environment Components for AIX.