SYMPTOM:
When trying to show a full circle case, Turbo Post issues an error message similar to the following one:
========================================
SEVERE
Operation failed with unrecognized system exception.
SEVERE
An attempt to recover from a previous error has failed.
The application is likely to be in an unstable state.
========================================

When taking the same case from Turbo Pre (not entering General Mode) > Solver > into Turbo Post the Turbo Report fails to load and Turbo Post issues an error message similar to the following one:
==========================================================
WARNING
Failed to initialize component 'Component 1' in
domain 'R1' for conversion type 'Cartesian to Turbo'.
ERROR
Cannot find turbo variable 'Streamwise Location'.
Turbo mode may not be initialized properly.
ERROR
Cannot evaluate 'minVal' on 'Streamwise Plot of Pt Line' as it does not have points.
===========================================================

PROBLEM:
Turbo Pre writes incomplete TURBO POST DATA information when CFX-Pre is restarted in Turbo Mode using a def file.


WORKAROUND:
No workaround is currently available.

FIXED IN:
ANSYS CFX Release 11.0 Service Pack 1.