User runs an analysis with the REINF265 elements without error. He leaves solution, re-enters and tries to resolve. He gets the error message below. What is the meaning of this message and what is the workaround?

--------------------------------------------------------------
ERROR MESSAGE RECEIVED:
*** ERROR ***
"No base element is found for reinforcing Element x.
Use of isolated reinforcing elements is not permitted."
---------------------------------------------------------------


This is a code defect at 11.0 (Defect report 62469) due to the new internal node created during the solution for the base element to hold pressure DOFs. Reinforcing elements failed to recognize the base elements due to this change in base element connectivity. It will be corrected at 12.0.

As a workaround, run sequential solves without leaving /solu session.





Show Form
No comments yet. Be the first to add a comment!