**** Entered By: rlange @ 12/14/2007 04:53 PM ****
Q. I am trying to use intermediate transient results from CFX as part of a one-way FSI analysis in WB Simulation to perform a Structural/Thermal analysis. However, Simulation does not seem to be able to import the appropriate data. What could be wrong?

A. If only selected variables are stored in the CFX results file, it is possible that CFX-Post will not have enough information to compute the necessary data to transfer to WB Simulation. In order to get around this issue ask for standard output in CFX-Pre for the Transient results set.


**** Entered By: rlange @ 12/14/2007 04:53 PM ****
Q. I am trying to use intermediate transient results from CFX as part of a one-way FSI analysis in WB Simulation to perform a Structural/Thermal analysis. However, Simulation does not seem to be able to import the appropriate data. What could be wrong?

A. If only selected variables are stored in the CFX results file, it is possible that CFX-Post will not have enough information to compute the necessary data to transfer to WB Simulation. In order to get around this issue ask for standard output in CFX-Pre for the Transient results set.





Show Form
No comments yet. Be the first to add a comment!