Class 3 Error
SYMPTOM:
A case using the transition model may give incorrect results and may incorrectly predict the transition location.
PROBLEM:
There is a coding error in the calculation of F_length (the length of the transition zone) as a function of the transition onset Reynolds number Re_theta_t, for values of Re_theta_t in the range of approximately 600 and 1200 (see the attached plot). This is expected to have little impact on mo
WORKAROUND: No workaround is currently available. FIXED IN: ANSYS CFX Release 12.0. A custom executable for ANSYS CFX 11.0 SP1 is available on request. |
||
|