KNOWN ISSUE: Time and Timestep related expressions may not be updated for final timestep


SYMPTOM:
In a transient calculation, timestep related expressions such as 'Current Timestep', 'Accumulated Timestep' and 'Time' may not be updated to their correct values when the final timestep is loaded. Instead, they may be set to the default values of -1, -1 and zero respectively. Values for intermediate transient results files are unaffected.

PROBLEM:
This is due to a bug in CFD-Post expression handling.

WORKAROUND:
No workaround is currently available.

FIXED IN:
ANSYS CFX Release 12.1.