bad Scrolledlistbox index "-1": must be active, anchor, end, @x,y, number, or a pattern


Problem Description: When the HPC Setup Category in ANSYS Launcher V12.0.1 is selected, it shows the following error:
-------------------------------------
ERROR MESSAGE RECEIVED:
bad Scrolledlistbox index "-1": must be active, anchor, end, @x,y, number, or a pattern
bad Scrolledlistbox index "-1": must be active, anchor, end, @x,y, number, or a pattern
while executing
"[$m_launcherObj GetPanel] DisplayHpcTab $m_hpcTab.f"
(object "::launcherGuiObj" method "::LauncherGui::HpcTabSelected" body line 3) ...

Resolution: This is most likely caused by an older version of ANSYS 12.0 (ANSYS 12.0 Preview 7) being installed at one point.

1.Rename the profiles.xml file to profiles.old from C:Documents and Settingsuser_nameApplication DataAnsysv120launcher
2.Restart the application.





Show Form