Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 Next

Why does license install fail on Windows XP Home OS which has no ethernet card?


If no ethernet card is installed on a system, the ANSYS FLEXlm Manager returns the Volume Disk ID as FLEXlm Host ID. There is no notification, that this is not an ethernet mac address. It has to...

Why are the temperatures obviously incorrect near the centerline
of my axisymmetric radiation analysis in ANSYS 9.0?


There is an error in the way the view factors are calculated near the<br>centerline. This has been corrected in ANSYS 10.0. [Ref: Defect 30593]

In Release 10.0, why are the modal participation factors different for a model with a doubly symmetric cross-section as opposed to an equivalent model with a slightly non-doubly symmetric cross-section?


Below are two examples of an open box modeled with SHELL elements. In one model, the cross-section is doubly symmetric (i.e., square cross-section). In the other model, the width of...

Why am I getting an error message about a convection surface
referencing an undefined material property? I am switching from a
temperature dependent film coefficient in load step 1 to a constant
value in load step 2 in ANSYS 9.0.


The program is improperly ramping the film coefficient from the<br>negative integer used as a pointer in load step 1 to the numerical<br>value specified in load step 2. The...

Why does pasting the following commands into the input window
at ANSYS 9.0 on the PC cause the graphics toolbar to be grayed out?

/clear
/prep7
et,1,42
rect,0,1,0,1
ames,all
fini

After this, the graphics toolbar is grayed out and we could not reactivate it.
If you add a blank line after the /clear the graphics toolbar is active again!


As you noticed this error is caused by the /clear command. It only happens<br>on the PC. The toolbar is driven by abbreviations in the start.ans file and with<br>this input the GUI...



I want to mesh a blade passage domain with inlet and outlet regions very close to the blade leading and trailing edges. The mesh lines bend down near the outlet region on the shroud surface. Movin the closest master control point helps a little, but does not solve the above problem.

Why does the topology line in that small region not follow the trend of topology lines of adjacent region?


<br><br>The topology line "bends" due to the fact that the blade is so close to the outlet, coupled with the node distribution on the inlet/outlet (which the user has no...

Why am I getting non-physical magnetic field results in Workbench 9.0 and 10.0?
I am using a line body to represent the coil.


This is a rare occurrence. Field results in models with conductors modeled as line bodies<br>can be grossly incorrect when the implied 3D conductor surface passes close to iron...



I've been using BladeGen/BladeGen+ in the past, and have recently upgraded to a BladeModeler and CFX-Flow License. What would be the proper procedure for getting an existing BladeGen design into DesignModeler and setting it up in CFX-Mesh? Workbench Start page gives me a "button" for "Blade Geometry" i.e. BladeGen, but not specifically BladeModeler and there is no reference anywhere to BladeEditor.


<br><br>The following procedure will walk you through how to launch BladeGen 10.0, import it into DesignModeler, and open the model in CFX-Mesh.<br><br>1) Start Wrokbench...

Why are deleted loads reappearing in a multi-frame restart?
I solved 3 Loadsteps. After the second loadstep I deleted some boundary
conditions. I ran the third loadstep completely. Everything looks fine. Then
I do a restart at time 2.5 with the option 'endstep'. After that the deleted
loads are back and I see a different result for this step than before.


The multi-frame restart has trouble with deleted boundary<br>conditions. This is addressed in the 4th sample input listing of<br>the Basic Analysis Guide Section 3.10.2. It...

Why does this long transient get slower the longer it runs in ANSYS 8.1?


This is a system-dependent problem caused by multi-point restarts and<br>increased memory used to read the load history file (file.ldhi). This error is<br>fixed in ANSYS 9.0 [Ref: ...

Unphysical particle and gas temperature values are encountered in particle tracking simulations in the CFX 10.0 Solver.


This problem may occur in the following cases:<br><br>- particle convective heat transfer only<br>- when using the particle evaporation model<br><br>The problem is...

Q) How can I get mass flow rate written out to minimal transient results files

A) You can either choose to select velocity and density, or more preferably you can set the following expert parameter

mfloip to trn files = T


Q) How can I get mass flow rate written out to minimal transient results files<br><br>A) You can either choose to select velocity and density, or more preferably you can set the...

Is there any way to plot the input force-deflection curve for Combin39 elements?


The macro (plt39rc) plots the real inputs for a COMBIN39. A sample input that demonstrates<br>it's use is included too. The macro does not do any data validity checking and ignores...

On the RSM Web Service (Remote Solution Manager Server), I get the following error while updating a server or queue


Server Error in '/CE' Application.
--------------------------------------------------------------------------------

QueryInterface for interface MSXML2.IXMLDOMDocument2 failed.
Description: An unhandled exception occurred during the execution of the current web request. Please review the stack trace for more information about the error and where it originated in the code.

Exception Details: System.InvalidCastException: QueryInterface for interface MSXML2.IXMLDOMDocument2 failed.

Source Error:

An unhandled exception was generated during the execution of the current web request. Information regarding the origin and location of the exception can be identified using the exception stack trace below.


Stack Trace:


[InvalidCastException: QueryInterface for interface MSXML2.IXMLDOMDocument2 failed.]
MSXML2.DOMDocumentClass.get_xml() +0
CE.XMLDocument..ctor(Object DOMDoc) +44
CE.JMUtilities.SaveJobManagerXML() +41
CE.Pages.Administration.ServerAdministration.CreateServer(Object sender, ImageClickEventArgs e) +117
System.Web.UI.WebControls.ImageButton.OnClick(ImageClickEventArgs e) +109
System.Web.UI.WebControls.ImageButton.System.Web.UI.IPostBackEventHandler.RaisePostBackEvent(String eventArgument) +69
System.Web.UI.Page.RaisePostBackEvent(IPostBackEventHandler sourceControl, String eventArgument) +18
System.Web.UI.Page.RaisePostBackEvent(NameValueCollection postData) +33
System.Web.UI.Page.ProcessRequestMain() +1292

--------------------------------------------------------------------------------

Version Information: Microsoft .NET Framework Version:1.1.4322.2300; ASP.NET Version:1.1.4322.2300


The MSXML2 libraries (.dll files) are missing on this computer.<br><br>Look for the presence of the files:<br><br> C:Windowssystem32MSXML2.dll<br>...

How can I visualize the direction (forward or backward) of the precessional modes in a rotor dynamic analysis?


In ANSYS 10.0 if you request both real and imaginary mode shapes to be written by the QRDAMP solver<br>with MODOPT,QRDAMP,Nmodes,FreqB,FreqE,ON, you can animate the whirling motion with the...

Is there a way in ANSYS 9.0 to apply an axial load to a point on an element
and this load keep axial to the section?


Yes. At 9.0 you can use the new element, FOLLW201 to do this.

Why is results evaluation taking 20 hours in Workbench 8.1
for a particular analysis?


Large arrays were created in a command snippet to apply pressure<br>to the model. The xml retrieval of these arrays is very slow. If the arrays<br>are deleted at the end of the...

Why can't I solve a harmonic magetic analysis with SOLID117 in ANSYS 8.1?
I could solve it in ANSYS 7.1.


You are running out of memory. Starting in 8.0 we added the ability to keep the<br>database data in memory during solution. For this model that adds about 150 MB to<br>the memory...

Why am I getting an incorrect field solution for this air coil in Workbench 9.0?
I created a large enclosure around the coil.


The mesh of the large enclosure becomes more coarse as it moves inward from<br>the surface. The line body representing the coil is entirely in a single element. It is<br>possible to...

Why do I get a message the message below in ANSYS 9.0 when I issue the CYCPHASE command?

*** WARNING *** CP= 20.870 TIME= 13:21:17

Phase angle evaluation (CYCPHASE cmd) is valid only for nodal-diameter
solutions greater than 0 and less than N/2 (N = number of sectors in
the full 360 degrees model). Current nodal-diameter is 7.

I have 15 sectors and I am reading the results for ND = 7. 0 < ND = 7 < 7.5


You didn't issued the SET command which is required for CYCPAHSE. An error<br>trap has been added in ANSYS 10.0 to alert the user to this.<br><br>[Ref: Defect 30956]


I get the following error in the ANSYS CFX-Solver


+--------------------------------------------------------------------+
| ERROR #001100279 has occurred in subroutine ErrAction.
| Message:
| Illegal argument in call back function areaAve on locale BCP1
|
|
| +--------------------------------------------------------------------+

+--------------------------------------------------------------------+
| ERROR #001100279 has occurred in subroutine ErrAction.
| Message:
| Stopped in routine SU_CBCK_GVAR
|
|
+--------------------------------------------------------------------+

+--------------------------------------------------------------------+
| An error has occurred in cfx5solve:
|
| The CFX-5 solver exited with return code 1. No results file has
| been created.
+--------------------------------------------------------------------+


<br>The arguments to the call back functions have to be variables. The call back functions are areAve, areaInt, massflowAve ... etc. So, you cannot pass a CEL expression as an argument to a...

For a transient run in CFX 10.0, how can I show the residuals at each coefficient loop and not just at the end of each timestep?


In CFX-Pre:<br>Double click on the "output control" section of the model tree<br>Click on the "monitor" tab<br>Tick the "monitor...

In a steady state coal combustion calculation it is sometimes useful to be able to set a different Physical Timescale for the mass fractions involved in NOx reactions. In CFX-Pre it is only possible to set a single Physical Timescale value for all mass fraction components.


The Physical Timescale for individual mass fraction components, in a definition file named ¿defilename.def¿, can be changed using the following method.<br><br>1: From the...

SYMPTOM:
When trying to start CFX-Pre within Workbench, an error dialog box appears with the title 'Error in AdvancedCFD Applet'. The following error message is contained in the dialog:

'error in onActivate: socketError: Socket::Socket ' listen'.

When pressing 'OK' on the dialog, Workbench shuts down.

PROBLEM:
The cause of this error is a bad interaction between Ansys CFX software and the McAfee firewall software.


WORKAROUND:<br>1) Disable the McAfee firewall to allow CFX programs to run within Workbench,<br><br>OR,<br><br>2) Add Workbench and the CFX programs to the list of...

Class 3 Error

SYMPTOM:
When using a real gas or an ideal gas with the Total Energy equation, and Static Temperature is specified on an Opening type boundary, the computed Total Temperature field depends on the angle between the velocity field and the boundary normal, which is incorrect.

PROBLEM:
There is a coding error in the calculation of Total Enthalpy for en


WORKAROUND:<br>Use the 'Opening Temperature' option rather than 'Static Temperature'.<br><br>FIXED IN:<br>Release 11.0. Custom 10.0 solver available upon...