Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 Next

Q.: The ICEM CFD 10.0.1 Pro/E mesher interface for Linux 64bit amd doesn't run with the ansys license feature pipro.

A.: Instead of the Pro/E mesher interface for Linux 64bit amd the linux 32bit version can be installed.


Q.: The ICEM CFD 10.0.1 Pro/E mesher interface for Linux 64bit amd doesn't run with the ansys license feature pipro.<br><br>A.: Instead of the Pro/E mesher interface for Linux...

How can I easily plot "resultant temperature" in CFX-Post 10.0 ? - is there an easy way to do this?


You will need to model radiation in your simulation and then run the comfort factor macros (TOOLS/Macros/Comfort factors).<br>The macros will give you resultant temperature and mean radiant...

I want to perform an AC electromagnetic analysis in which a transmitting ("TX") coil producing harmonically varying source field is physically very small compared to the extent of the surrounding domain. To keep element count down, I wish the mesh at the field source to be as coarse as possible.

I found that SOURC36 used in a coarse SOLID117 mesh resulted in an inaccurate representation of the field source. Explicit modeling of the geometry of the TX coil leads to undesirably high element count. What would you suggest as an alternative?


:


Two options to consider are:<br><br>1) SOLID97 model using F,,CSGx/y/z excitation (see attached model02.inp). This is acceptable when highly permeable regions do not exist in the...

QUESTION:

Do you have an example demonstrating the procedure for calculating the response of a piezo transducer operating under hydrostatic pressure?


ANSWER:

Working files for a prestressed harmonic response analysis are attached to this solution. Seems to work ok, though I'm a little uncertain about the following:

1) Electrodes are electrically open (seperate CP's on VOLT) during static prestress run (hydrostatic pressure applied). Should they be grounded? Unsure. May be a function of operating conditions. Simple changes could be made to the input file to investigate further.
2) Postprocessing: range in voltage in the attached voltage animation increases dramatically w/prestress pressure (I ran several cases). I assume that the actual working voltage, displacements, stresses would be a superposition of those obtained from prestress static run and the subsequent harmonic response results (add a DC bias to the AC response). This has not been done here but is relatively straightforward.


QUESTION:<br><br>Do you have an example demonstrating the procedure for calculating the response of a piezo transducer operating under hydrostatic...

hen installing Workbench 11.0 Preview 3 on an HPUX machine, the user receives the following errors in the install.err:
>>>--------------------------------------->
ANSYS 110 installation: Sat Mar 04 11:35:39 EST 2006
/usr/lib/dld.sl: Can't shl_load() a library containing Thread Local Storage: /usr/lib/libcps.2
/usr/lib/dld.sl: Exec format error
/usr/lib/dld.sl: Can't shl_load() a library containing Thread Local Storage: /ansys_inc/v110/aisol/dll/hp32/libwbpostmesh.sl
/usr/lib/dld.sl: Exec format error
/usr/lib/dld.sl: Can't shl_load() a library containing Thread Local Storage: /indirect/stapps/apps1/ansys_inc/v110/aisol/lib/hp32/libcadoe.sl
/usr/lib/dld.sl: Exec format error
/usr/lib/dld.sl: Can't shl_load() a library containing Thread Local Storage: /indirect/stapps/apps1/ansys_inc/v110/aisol/lib/hp32/libcadoe.sl
/usr/lib/dld.sl: Exec format error
>>>--------------------------------------->

What causes this error?


The user did not have the following patches installed:<br>PHSS_30049 Id (1)<br>PHSS_30871 Xserver Cumulative Patch<br><br>After installing the patches, the libraries should...


The user has ICEM CFD licenses but no AI*Environment license:
When he writes an input file for abaqus via the "output" tab, only the node definitions are in the input file and not the element definitions, means the ELSET definitions are missing.


<br>Only those families/parts are written out which have an element type definition and a boundary condition. Other elements will be omitted.<br>This means, if you need more than the...

I will be running a very large problem (15 million node) with CFX 10.0

For the problem size indicated above, how much RAM is required to run the programs fluidly and the solver in a reasonable amount of time? How many partitions should be used, given that I have a network of 2GB machines?


<br><br>The first limit you would hit for this size of problem is the partitioning limit. Partitioning is a serial process, so your host machine has to have enough memory to do it. ...

When I try to launch the help of ICEM CFD 10.0.1 on a linux64_amd system it fails with the message:

START HELP ENGINE
Platform = Linux
Help being launched for linux64_amd
Can't find Java help executable: /usr/local/ansysinc/v100/icemcfd/linux64_amd/lib/jre/linux64_amd/bin/java
Unable to start AI help system. Please check you help installation.


<br>In the standart installation of ICEM CFD 10.0 with SP1 (also with additional SP2) there's only the directory<br> ../linux64_amd/lib/jre/linux64<br>but not<br> ...



In a CFX-10.0 simulation setup (2 phases with many domains), starting the CFX solver always lead to an error:

*** INSUFFICIENT CATALOGUE SIZE ***
Action required : Increase the file catalogue size.

The recommended action, i.e. increasing the factor "Catalogue Size Multiplier" in the ccl, does not have any influence, however.


<br><br>Increasing the factor "Catalogue Size Multiplier" is not enough in some rare cases, because the first estimation of memory for the MMS is not influenced by the...

When importing a multi-domain mesh from ICEM CFD to CFX-Pre the mesh on the domain interfaces look like a checkerboard. How to correct this?


The reason are non-uniform face orientations of the shell elements on the interface between the volumes. The surface mesh orientations have to be fixed in ICEM CFD as follows:<br><br> ...

SYMPTOM:
When attempting to compile a custom Export executable on Windows, and following the steps in the on-line Ansys CFX documentation, errors similar to the following are generated at the link stage and the compilation fails:

Linking...
libmeshexport.lib(cfxExport.o) : error LNK2001: unresolved external symbol _pgtCloseAPI
libmeshexport.lib(cfxExport.o) : error LNK2001: unresolved external symbol _pgtLastError
libmeshexport.lib(cfxExport.o) : error LNK2001: unresolved external symbol _pgtLoadCCL
libmeshexport.lib(cfxExport.o) : error LNK2001: unresolved external symbol _pgtOpenAPI
libmeshexport.lib(cfxExport.o) : error LNK2001: unresolved external symbol _pgtDomainRotationVelocity
...
...
Release/CFXExport2.exe : fatal error LNK1120: 12 unresolved externals
Error executing link.exe.

Similar errors are produced when attempting to compile on Unix platforms.

PROBLEM:
The documentation fails to mention the full list of library files which must be included when compiling any custom Export programs.


WORKAROUND:<br>Make sure that the 'pgtapi' and 'units' libraries are added to the list to link against when compiling.<br><br>On Unix, use the...

The user loaded a blocking that was ok before and now the outer edges of one volume are blue and not white. All the outer faces of the block belonging to a single material are not projected.


The reason for the non-projected outer faces of a single volume part (here: FLUID) was a SHARED WALLS definition between that part and another part that was missing in the part list for some...

My calculation runs O.K. in serial mode but stalls or freezes near the start of the solver step when I run in parallel. What is the problem?


Does your calculation use non-local CEL functions (like areaAve and massFlowAve) as well as initialisation the variables in a domain using the "Automatic" option? If so, then the...

Why is there no DesignXplorer option in the Workbench Simulation 10.0 Project page?
I was able to reproduce this in-house and this doesn't require any license at all.


The problems are the checks in the project page ¿CanDoDX¿ and ¿CanViewDX¿ in Contexts.xml.<br>These verify that a DX license exists, however, the checks are not...

Why does ANSYS 10.0 32-bit version allow users to specify -m of 10000mb?


We were able to duplicate this on our machines and have created Defect ID: 42892.<br>This only affected Windows 32-bit systems. The defect has been fixed and verified and will be implemented...

When a user tries to borrow a license for Harvard Thermal Products, the Borrow utility states there are no licenses available to borrow.
The license key is correct with the borrowable features in it.
What causes this?


There was a problem with the current borrowing utility and the fix is to download the latest License Manager utilities from the following link:<br><br><a target=_blank...

The user's tetin file contains only few geometry entities but it's size is extremely large. Also, saving even fewer visible entities doesn't reduce the size in the same way.


Due to lots of save operations the header grew enormously because comment lines are added with each saving. These comments don't contain necessary information and can be deleted by editing...

Are there any examples of MPC contact surface-based constraint
using the force-distributed surface constraint method?


Yes, please see the attached ANSYS 10.0 input file. It applies<br> an out-of-plane moment to the top surface of a block via a<br> remote pilot node. The reactions verify the...

Environment and Solution options are grayed out in the simulation (new or solved). Similar to working in read-only mode, but the product is reading a license and does not state that it is in read-only mode. Multiple seats are reading the same license and having no similar issues. This is specific to a single machine.


In Simulation<br><br> View > Physics Filter > Select: Structural (or Thermal, or Electromagnetic)

The Ansys 10.0 Workbench plug-in menu is not available in OneSpace Designer 2005

- The plug-in for OneSpace Designer 2005 was selected during Workbench setup screen, but the plugin does not appear in OneSpace Designer.
- There may be no Add-Ins Tab under OneSpace Designer > Applications > Modules
- Or, there is no "Ansys 10.0" checkbox under OneSpace Designer > Applications > Modules > Add-Ins tab.


There was a known issue with OneSpace Designer 2005 v13.20 whereby third-party Add-Ins (Plug-ins) were not recognized when installed on a<br> non-English operating system or non-English...

Does ANSYS LS-DYNA PC support the Windows XP 64-bit operating system?


There was a bug in the license generating software that was fixed today<br> (March 29, 2006). Any ANSYS LS-DYNA PC license generated before today<br> for the Windows XP...

######## WORK NOTES COPIED FROM INCIDENT 489171 ########
Q. Is there an example of calculating Joule heating in ANSYS and inputting the results as a volumetric load for CFX?

A. Yes, the example is an attachment to this solution.


######## WORK NOTES COPIED FROM INCIDENT 489171 ########<br>Q. Is there an example of calculating Joule heating in ANSYS and inputting the results as a volumetric load for...

ANSYS TurboGrid 10 SP1 on an AMD Athlon 64 machine which has CENTOS Linux installed does not run. I get the following error message:

/home/cfx/cfxroot/TurboGrid-10.0/bin/linux/TGGui_ogl.exe: /home/cfx/cfxroot/TurboGrid-10.0/lib/linux/libgcc_s.so.1: version `GCC_3.3' not found (required by /usr/lib/libstdc++.so.6)
Warning!

CFX-TurboGrid exited with return code 1

Notes:
1. CENTOS is a clone of the officially certified (for CFX) Redhat Linux Enterprise 3
2. On a similar machine with Gentoo Linux installed, ANSYS TurboGrid 10 SP1 is running fine.


The following should resolve the problem with ANSYS TurboGrid 10 SP1 on your AMD Athlon 64 with CENTOS Linux:<br><br>1) Rename /home/cfx/cfxroot/TurboGrid-10.0/lib/linux/libgcc_s.so.1...

ICEM CFD crashes with 'Speicherschutzverletzung' reading the user's tetin file.


The user defined a part with a name containing a space character. Editing the tetin and replace this name by another without space character fixes the problem.

How to change the background color for CFX-Post under workbench? The menu options for the viewer were not the same as for standalone Post and seem to have no option for changing the background of the viewer.


In Workbench, this is done from the Projects page under the Tools--Options menu. All pages then conform to the standard set by the project page.<br><br><br><br>Q: Is it...