Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 Next

Class 3 Error

SYMPTOM:
If USER_GETVAR is used to get gradients of non-scalar variables then the results are incorrect.

PROBLEM:
The documentation says that the result of the call to USER_GETVAR takes the form (NGRAD,NLOC,NCOMPT); however, the program actually returns the result as (NGRAD*NCOMPT,NLOC). For scalar variables the gradients


WORKAROUND:<br>No workaround is currently available.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Service Pack 1.

Are there any examples comparing SOLSH190 results to those of SHELL181?


Yes, please see the attached ANSYS 11.0 example. A 0/90/0/90/0/90<br> laminate is modeled with a single SOLSH190 element through the<br> thickness, two SOLSH190 elements...

My Simulation 11.0 model does not have the same point mass defined in Simulation 10.0 SP1. Why?


Defect 57713 was filed and fixed in the daily build of ANSYS Workbench Simulation 12.0 and is also<br> expected to make it into the first service pack for ANSYS Workbench 11.0. ANSYS...

Class 3 Error

SYMPTOM:
When backup, transient or the final results file is written, a run using the expert parameter "rotational offset for post" may have problems in several ways. Symptoms include any of the following.

a) The solver may fail whilst trying to write the results file with the following error:
Error detected by routine DELDAT
CDANAM = ROTOFF
CRESLT = NONE

Current Directory : /FLOW/GEOMETRY

b) The solver fails in the timestep immediately after writing a backup or transient file with errors about mesh quality.

c) There is a large spike in the residuals just after writing a backup or transient file.

d) The expert parameter fails to have any effect.

PROBLEM:
There are several problems.

1) A memory overwrite occurs when a second or subsequent results file is written. This will often lead to a vertex coordinate being overwritten and will normally lead to a large spike in residuals, but sometimes leads to problems being reported with mesh quality. This defect has been present for several releases.

2) If the specified rotational offset is applied to a stationary domain, then a defect which was introduced in release 10.0 causes the solver to stop with the error listed in symptom (a) above.

3) If the specified rotational offset is applied to a rotating domain, then the expert parameter ha


WORKAROUND:<br>No workaround is currently available.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Service Pack 1.

In Workbench Simulation, if you select the Report Preview tab, then Send To > Microsoft Word,
Word crashes with the following error dialog:

Microsoft Office Word has encountered a problem and needs to close. We are sorry for the incovenience.
AppNane winword.exe
...etc.

This problem is usually observed with large Simulation databases i.e (150MB / 15 environments)
and Office Word 2000, and Office Word 2003


<br> - This problem is fixed with Office Word 2007<br><br>- A workaround for earlier versions of Office are:<br> Generate the Report,<br> Publish > Save...

Q. Why has the "ANSYS Multiphysics CFX-Flo" license been replaced by "ANSYS
Multiphysics 11.0". Has any functionality is been removed
with this switch?

A. If you are running Version 11.0, the answer is that no functionality is removed. At Version 11.0, customers no longer need the ACFX_FLOTRAN_UPGRADE feature (the CFX-Flo part). However, if the customer wishes to continue to run prior versions, CFX will need the additional feature.


Q. Why has the "ANSYS Multiphysics CFX-Flo" license been replaced by "ANSYS<br>Multiphysics 11.0". Has any functionality is been removed<br>with this...

To model a circuit-fed coil using SOLID97, we have to choose the AX,AY,AZ,CURR,EMF option. This option needs real constants, including CARE (coil cross-sectional area), VOLU (volume of the modeled conductor), and DIRX, DIRY, DIRZ (unit vectors that describe the direction of current flow), etc. How do I determine the real constants of circuit-fed torus stranded-coils using SOLID97,3, especially the CARE item?


See the attached model of a stranded toroidal air coil using SOLID97. The coil was divided into multiple sectors, each having unique real constants for fill factor and cross section area. The...

Class 3 Error

SYMPTOM:
A transient rotor-stator case run in parallel, when two domains have different pitches, may behave oddly. Symptoms include failing in CFX Release 10.0 or Release 11.0, when the case previously ran without problems in CFX-5.7.1, failing when the number of passages is changed or failing when the physical models are simplified.

PROBLEM:
In ANSYS CFX Release 10.0, dynamic ordering of the boundary faces on the GGI interface sides was introduced in order to allow the support of non-overlap conditions. The calculated rotation matrix does not take proper account of this re-ordering and is therefore incorrect, which leads to problems when the two domains have different pitches. The exact behaviour depends on the partitioning


WORKAROUND:<br>No workaround is currently available.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Service Pack 1.

Class 3 Error

SYMPTOM:
A multiphase case with bulk initial conditions set for turbulence or radiation quantities does not use the correct initial conditions.

PROBLEM:
An error prevents the copying of a single initial condition for turbulence or radiation to all the phases in the domain. Therefore, the remain phases will be initialized as Automatic, regardless of th


WORKAROUND:<br>No workaround is currently available.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Service Pack 1.

When I attempt to start Ansys Workbench, it produces "Permission Denied" script errors.
The user may also describe the following symptoms:
- Grey screen
- Gray screen
-Blank screen
- Windows Panes appear to be split
- Unable to import or attach any geometry files, even simple models that worked previously.
- Plugin Error : Attach Failed for any model
- Workbench stops responding (locks-up or freezes).


<br><br>1. In the DM or Simulation Toolbar, Try:<br> View > Windows > Reset Layout<br><br><br>2. Reset all of the Workbench settings and...

Q. I am using the PLANE67 element in ANSYS and have achieved a solution in steady state. However, when I try to get the same result with the transient algorithm, the case immediately diverges. What can I do about it?

A. The fault lies in the value of THETA on the TINTP command. The value of 0.5, corresponding to the Crank-Nicholson approach to transients, is not stable for this problem. Set the value to 1.0, corresponding to a backward difference approach, with the command TINTP,,,,1.0.


Q. I am using the PLANE67 element in ANSYS and have achieved a solution in steady state. However, when I try to get the same result with the transient algorithm, the case immediately diverges. ...

Is there a version of the ANSYS CFX 11.0 Update 1 for Linux 64bit?


From the ANSYS Customer Portal <a target=_blank href="http://www1.ansys.com/customer">http://www1.ansys.com/customer</a>http://www1.ansys.com/customer<br>you can...



I would like to run several cases in CFX one by one using a specific parallel method. How can I define this in Perl?


<br><br>To run a case, say using the definition file case1.def, one can type the following command into the command line (a command window can be obtaining from the CFX Launcher by:...

When using the ADAMS.MAC macro to generate MNFs (Modal Neutral Files) for ADAMS/Flex, the resulting file is very large. What can be done to reduce the file size?


The MNF can be optimized in the ADAMS/Flex Toolkit program, such as computing the inertia invariants, removing internal element faces, and/or using single precision.<br>The procedure can...

Class 3 Error

SYMPTOM:
There are errors in solution values such as pressure, temperature, density and entropy for cases with compressible fluids when running with the total energy equation.

PROBLEM:
For the equations discretisation, the derivative were integrated over the new mesh volumes instead of the old me


WORKAROUND:<br>No workaround is currently available.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Service Pack 1.

Question:
Why doesn't Microsoft Visual C++ recognize the Intel FORTRAN project "ad_usrsub.vfproj" when I start AUTODYN user subroutine project "ad_usrsub.sln"?

Answer:
This error indicates that the Intel Visual FORTRAN compiler 9.x Integrations in Microsoft Visual Studio is not installed properly. You need to

1. Uninstall Intel Visual FORTRAN v9.x all components.
2. Uninstall Microsoft Visual C++ 2003.
3. Re-install Microsoft Visual C++ 2003.
4. Re-install Intel FORTRAN v9.x. Make sure the Intel Visual FORTRAN compiler 9.x Integrations in Microsoft Visual Studio is installed successfully.


Question:<br>Why doesn't Microsoft Visual C++ recognize the Intel FORTRAN project "ad_usrsub.vfproj" when I start AUTODYN user subroutine project...

SYMPTOM:
On Windows 64bit, CFX-Pre crashes when creating a domain interface at a fluid-solid interface in a model including radiation with the error:

SEVERE
Operation failed. Insufficient memory.


PROBLEM:
This is due to incorrect logic in the code leading to a memory access violation.


WORKAROUND:<br>Run the case on an alternative OS - for example Windows 32bit..<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1.

SYMPTOM:
When setting up a model in CFX-Pre with the External Coupling set to ANSYS Multifield or ANSYS Multifield via Prep7, the maximum number of iterations in a steady-state calculation is defaulted to 100, and the maximum number of coefficient loops in a transient case is defaulted to 10. Both of these numbers should have defaults of 3.

PROBLEM:
This is due to the default values specification not using information about the physical model.


WORKAROUND:<br>Change the values from their default values of 100 and 10.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1.

SYMPTOM:
When importing a case with non-constant physics, for example a case with different fluids in two disjoint domains, the Fluids List in one domain is modifed to be the same as in the other. This leads to the physics of the case being changed, potentially with the user not being aware.

PROBLEM:
This is due to CFX-Pre not noting that the case has non-constant physics.


WORKAROUND:<br>Use the Environment Variable CFX5_NO_CONSTANT_PHYSICS.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1. The code has been modified to automatically allow...

SYMPTOM:
If a def file from CFX 10 for a transient rotor-stator case, which has a a domain interface with Transformation Type = None and Pitch Angles set, is run in the CFX 11 Solver, it is possible to get an error message of the form:

+------------------------------------------------------------------------------+
| An error has occurred in cfx5solve: |
| |
| Errors were encountered in the CFX Command Language for this run: |
| |
| Error: Parameter 'Pitch Angle Side1' is not allowed in /FLOW/DOM- |
| AIN INTERFACE:Bot Interface/INTERFACE MODELS/PITCH CHANGE |
| Error: Parameter 'Pitch Angle Side2' is not allowed in /FLOW/DOM- |
| AIN INTERFACE:Bot Interface/INTERFACE MODELS/PITCH CHANGE |
| Error: Parameter 'Pitch Angle Side1' is not allowed in /FLOW/DOM- |
| AIN INTERFACE:Top Interface/INTERFACE MODELS/PITCH CHANGE |
| Error: Parameter 'Pitch Angle Side2' is not allowed in /FLOW/DOM- |
| AIN INTERFACE:Top Interface/INTERFACE MODELS/PITCH CHANGE |
+------------------------------------------------------------------------------+


PROBLEM:
This is due to a change in the CCL required for CFX 11, and the CCL update mechanism not working correctly.


WORKAROUND:<br>Import the case into CFX-Pre 11 and write a new def file.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1.

SYMPTOM:
If a case set up in CFX 10 with Molar Mass set in Mixture Properties is read into CFX Pre 11, one gets an error like:

The parameter "Molar Mass" is present in the object "/LIBRARY/MATERIAL:Permeating Mixture/MIXTURE PROPERTIES/EQUATION OF STATE" but it is not physically valid.

Anologously, if one tries to set up a case in CFX 11, it is not possible to set the Molar Mass on the Mixture Properties tab, and CFX-Pre gives the error:

ERROR
CCL validation failed with message:
Error: The essential parameter 'Molar Mass' is missing from /LIBRARY/MATERIAL:Permeating Mixture/MIXTURE PROPERTIES/EQUATION OF STATE


PROBLEM:
This is due to an inconsistency between the RULES file and the CFX-Pre Physics file.


WORKAROUND:<br>Edit the Command File manually to set the Molar Mass value.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1.

SYMPTOM:
CFX-Pre does not allow the user to set a porous-solid domain interface to be 1-1 even though the Solver allows this. This means that the user cannot easily set up a case with a multiphase porous domain and a conducting solid domain.

PROBLEM:
This is due to CFX-Pre being unaware of a Solver improvement.


WORKAROUND:<br>Edit the Command File manually to include the setting required.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1.

SYMPTOM:
Using function@location in the CFX 11 product gives errors, which may not always indicate the cause of the problem.

PROBLEM:
The official documented format for a callback is, and always has been, function()@location, although function@location usually works correctly. In CFX 11, it was decided to remove this latter functionality.


WORKAROUND:<br>Use function()@location.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1. The use of function@location has been reintroduced, but with a warning message...

SYMPTOM:
Exporting a multiple rotating domain case with several different axes of rotation, which are not defined in the same coordinate frame as the stationary domain, causes the axes to be wrongly oriented and thus the domains can appear to rotate incorrectly or in some cases appear not to be in the correct position.

PROBLEM:
This is due to the export code incorrectly calculating the effect of rotation.


WORKAROUND:<br>No workaround is currently available.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Update 1.

SYMPTOM:
If ANSYS CFX-11.0 Update 1 is installed as well as standard CFX-11.0, then, when running the ANSYS CFX-11.0 Update 1 Solver with a res file from the ANSYS CFX-11.0 Solver as the definition file, the ANSYS CFX-11.0 executable is used in error. If the res file is read into CFX-Pre, and a new def file is written, then this problem also happens.

PROBLEM:
In the execution control part of the CCL of the res file, the executable is set to be the ANSYS CFX-11.0 one. This execution control can be passed through CFX-Pre to a nee def file.


WORKAROUND:<br>Delete the execution control part from the CCL.<br><br>FIXED IN:<br>ANSYS CFX Release 11.0 Service Pack 1.