SiteMap Page 29


Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 Next

FLUENT - How to set the graphics window background, foreground and zone colors


How can we change the colors used in the graphics window?<br>The graphics window colors can be changed with text user interface (TUI) commands.<br><br>For example, in the FLUENT...

Maximum cell skweness


In Tgrid, there might be a need to access maximum cell skewness( Mesh--->Tri/Tet/Controls/Refinement) through<br>a scheme command. A typical application of this command is in a Tgrid...

Mixsim2: Heat exchanger coil or tube bundle as porous media zone?


A tank contains one or more helical heat exchanger coil(s), or bundles of vertical heat exchanger tubes in a circular arrangement. In both cases, resolving the geometry of these entities results...

MixSim, Windows: "Add Object:" button list is empty -- cannot add any object to Tank


A new Mixsim installation. Run the first session. Create a new model. Go to the "Cylindrical Tank" model: The "ADD Object:" button list in the right column of the...

POLYDATA : error message of the type : assert "nLen < (INT_MAX / sizeof(wxChar)) ..."


This trouble is encountered when running POLYDATA in wx mode and when the .p3rc file is missing<br>Add a .p3rc file that should at least contain the following information:<br>MAXLEN 90

Changing kill-script name and path


Scheme file attached below would create $HOME/kill-fluent<PID> script in user specified directory. Name<br>of the script file could also be changed. The usuage of which is as...

Acoustics module does not work in parallel -FLUENT 6.0.20


Acoustic Model runs on Single CPU. However the same case doesn't run in parallel. The acoustic scheme file is available.<br>Acoustic Model in FLUENT-6.0.20 will not run on parallel if...

Reynolds stress model with realizability based epsilon equation


When highly separated and vortical flow is considered, the eddy viscosity models, i.e., general one and two equation models, fail to predict the outstanding flow features correctly, partly due to...

POLYFLOW - How to invoke POLYFLOW with a UDF under POLYMAN environment? What are the valid filenames for a UDF?


Under the POLYMAN environment, when invoking POLYFLOW with a UDF, it does not seem to work.<br>It is possible to run POLYFLOW with a UDF from the POLYMAN enviroment. But care must be taken...

Why am I getting "can't open DISPLAY" when using telnet?


Suppose you run your job on a UNIX box and want to postprocess on a PC by remotely logging in, you get an error "can't open display".<br>FIDAP and GAMBIT automatically...

Shear stress on surface


Need macro to give shear stress<br>Macro used in the following code snippet:<br><br>{<br>real...

/sbin/loader: Fatal Error: Cannot map library libfor.so


When trying to run FLUENT you get the following error message:<br><br>/sbin/loader: Fatal Error: Cannot map library libfor.so<br><br>Comments: The latest version of fluent...

FLUENT or TGRID hangs on AIX


There were changes made to libc on AIX 4.3.3, AIX 5.1, and AIX 5.2.<br><br>If the maintenance level of libc.a is at the following levels, cortex will hang on socket...

difference between BOUNDARY_HEAT_FLUX(f,tf) and BOUNDARY_RAD_HEAT_FLUX(f,tf)


User wanted to use two macros but encountered some discrepancies between the udf results and what FLUENT prints in the GUI Report-Fluxes panel.<br>Two macros are available to get heat...

species source terms


source term for a species is added but it does not show up in the mass imbalance<br>Species sources are not accounted for in the mass imbalance in the solver. This is something that should...

particle tracks discrepancy in FLUENT 6.1.18 parallel distributed memory


User wrote:<br>I have three different FLUENT furnace simulations which have been run on v6.0.20 succesfully on serial solver. When I load any of these in v6.1.18 (serial or parll), the...

How to use load distribution vector for parallel processing with CPUs of different speed


When using the parallel solver, the default partitioning method will try to put the same number of cells in each partition. For example, when a case file is loaded into a parallel session using 3...

Model specific cpu time calculation


How do you find out the cpu time taken in solving each equation in your model?<br>The following text command can be used to find out the cpu time taken in solving each model...

POLYFLOW : The motion of the impeller is wrong (MST calculation)


When running a MST calculation, the impeller undergoes a wrong motion.<br>The parameters defining the impeller motion may be wrong, and have to be checked.<br>If the calculation starts...

Primitive Error at Node 0: dump_face out of memory


Problem Description:<br><br>You have just purchased a dual processor machine with 4 GB of RAM. You have a large case file (between 3 - 4 million cells). While reading in the case file...

Node values not calculated properly for UDM's in a parallel solver


When UDM's are used to store certain values, the values are stored for cells. For a parallel version of Fluent, if node<br>values are displayed for the UDM's there is...

POLYDATA - Polydata does not work in a remote session (over a network)


I am running polydata from another machine, sometimes the buttons at the top and the clickable text menus do not respond. What is happening?<br><br>The NumLock key interferes with the...

Mixsim2: Error: get-thread: invalid thread id (integer) or name (symbol)


When I want to create impeller surfaces, MixSim issues the error message...:<br> Error: get-thread: invalid thread id (integer) or name (symbol)<br>(This may also appear in other...

Mixsim2: Cannot have more than 8 impellers on the same shaft


When more than eight impellers are attached to the same shaft, MixSim fails most often to create a mesh.<br>Other features of MixSim are probably also affected by this...

Mixsim2: Windows: cannot use CAD file that is located in the Mixsim-Object-Library directory


When a new impeller is implemented as a new object class (by putting a new .mxo MixSim object file in e.g. the ...Fluent.Incmixsim2.0Mixsim-Object-Library directory), a ACIS (.sat) CAD file can be...