Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 Next

Icepak: Tips, Tricks and Best approaches to solve electronics applications


What are the commonly used techniques and tips and tricks to successfully solve electronics applications using Icepak?<br>The attached presentation discusses the...

What factors affect the modeling at high altitude and how to incorporate these in an Icepak Model?


Air properties as well as fan performance change with altitudes. In order to take these changes into effect users need to modify the air properties and correct the fan curve. The fan curve is...

POLYDATA - Trouble when converting an old polyflow result file; error message is "Polyflow not licensed"


When converting a POLYFLOW result wia POLYDATA, the procedure stops and generates the error message "Polyflow not licensed". The conversion is not performed. What can be...

POLYFLOW - how can we assign a pressure inside an internal flow problem


the inlet velocity boundary condition of an internal flow problem is imposed using a CSV file obrained from a former (upstream) calculation. The use is also interested in having a continious...

POLYFLOW - Trouble when invoking POLYFLOW from POLYMAN, an error message is issued "Program not found"


The trouble appears on a PC (32 or 64 bits). The complete error message is "Program not found. Check your configuration file of the environment variable POLYFLOW"<br>This may...

POLYMAT - Error: "Free store exhausted - No more memory space"


This message can be generated, although there is still planty space available. What can be done?<br>This could be related indeed to a lack of available disk space or memory...

solidification/Melting for pure component in V12.0.16


For Pure component solidificaiton ( when Tl = Ts) the temperature and liquid fractoin field is not correct.<br>This is a bug and is fixed in R12.1.<br>The workaroudn is:<br>1. ...

initialisation error with solidificaiton/Melting + species Transport model


segmentation violation is encountered while initialising the case which has Solidfication with species transport model and has multiple fluid zones in...

Solve an extrusion problem by cascaded approach using csv file


There are situations when its not possible to simulate the entire geometry at one go because of mesh and memory restrictions. In extrusion/coextrusion problem sometimes the die is so long that...

POLYMAN - a warning is issued when trying to select a CSV file that was not imported in POLYMAN structure


In a POLYDATA session called from POLYMAN, a CSV file is selected for initialising a solution, without importing it. When doing so, a warning is issued. Apparently it does not crash the...

How can I specify workspace memory allocation in Workbench 8.0 as is done in ANSYS with -m and -db?


The variables "AMK memory" and "AMK dbmemory" allow you to specify the ANSYS "workspace" and "database" memory allocation, respectively. ...

Early in a Block Lanczos solution I am getting a memory error
message during a SplitGraphOrder operation. What can I do about
that?


This error message refers to an operation performed by the METIS<br>reordering algorithm in the Sparse solver. It uses a lot of memory and<br>it appears it ran out on this model. A...

I am using PLANE55 for a thermal analysis and applying radiation by the radiosity method. There are convections elsewhere in the model. Is there a way to determine the heat lost from the radiation surfaces? The Element output table has HEAT RATE, but that is only for convection.


At ANSYS 8.1 you will be able to use *get to obtain the heat going to the space node:<br><br>*GET,aaa,RAD,1,NETHF<br><br>(replaced SPHF by NETHF)<br><br>This...

Why don't my listed ANSYS 8.0 displacement results with RSYS,1 match the plotted or
plot query results for the same nodes with /CYCEXPAND on?


The listed results are in RSYS,0 even though RSYS,1 was specified.<br>This is an error which is fixed in ANSYS 8.1 (Ref: Defect 20013)

Why am I getting different frequency values in ANSYS 8.0 with this model when
I request a different number of modes or a different frequency range.


Your model has MPC184 elements which are not supported at 8.0 by the<br>Block Lanczos solver due to their use of LaGrange Multipliers (see Assumptions<br>and Restrictions for MPC184.) ...

When using LMATRIX in the stand alone EMAG product
at ANSYS 8.0, I get the following error message. Why?

*** ERROR *** CP= 55.141 TIME= 14:42:33
The NLGEOM command is either not available for this version of ANSYS or
the appropriate product was not selected for this session.
Contact your ANSYS support person for more information.


The LMATRIX macro has an NLGEOM,OFF command which is generating<br>this message. This will be corrected in ANSYS 8.1.

Is ANSYS supported on the AMD processor?


ANSYS 6.0 is the first release of ANSYS to be certified on an AMD processor. This version of ANSYS has been tested on a Wallingford AMD dual processor machine using the XP Pro operating system. ...

When starting ParaMesh, the language is in French. Why?


Check the ParaMesh_en.qm file under ..:Ansys IncV80ParaMesh2.3, and make sure that the permissions for this file is "Full Control" for Everyone in the "Security"...

. I am running a FLOTRAN VOF problem and am getting the following error message. What should I do?


*** ERROR *** CP= 97.109 TIME= 09:59:42
The time increment at substep 1 for VOF advection is too small, stop.
Increment = 1.953125E-03.


The FLOTRAN time step is much too big. The VOF algorithm divides it as necessary, but stops when it has divided it too many times, because the VOF and flow solutions are too much out of...

Do you have an example that illustrates a way to determine nonlinear transient response to harmonically varying excitation?


The attached input file illustrates APDL usage to set up a transient analysis of a simply supported beam subjected to harmonically varying excitation (base acceleration). Nonlinearities can be...

Linearized stress data is now available in ANSYS 8.1 for BEAM188
and BEAM189, but the results do not appear to be correct. Why?


Defect 22494 was filed and fixed in the UP20040406 build of<br> ANSYS 9.0. The fix should also be available in the first service<br> pack for ANSYS 8.1, but this service pack...



When I enter setup in the drop test module, I receive many messages saying that elements attached to areas cannot be deleted, use ACLEAR instead. Why does this happen and/or do you know how to suppress these messages? The model seems to be fine after all the messages finish flashing by on the screen.


<br><br>The problem with this model is that areas on the exterior of the meshed volumes are themselves meshed. Upon entering setup, ANSYS deletes preexisting surface(s) onto which the...

Do customers need to install the additional HP-MLIB math software library that is listed in the Unix installation Guide (OS requirements)?


The mlib functionality should be archived into the application.<br>The customer should not have to buy it, or need it on their system.<br><br>The mlib library is supplied to...

In ANSYS 8.1, when the user changes the contact algorithm to pure Lagrange (KEYOPT(2)=3 or 4, the sign convention become negative for contact sliding distances for some of the CONTA17x elements. Why does this happen?


This is a code defect which will be corrected in the ANSYS 9.1 release. Absolute values (AASS/AASR) are correct.

I cannot access the NASTRAN to ANSYS translator that is available in
ANSYS FE Modeler 8.0. Does this capability require a special license?


Yes, in ANSYS Workbench 8.0, FE Modeler requires the "Interface for<br> NASTRAN" license (feature "int4nas"). Namely, when you try to access<br> ...