Previous 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 Next

How can I visualize the Drucker-Prager Cap model yield surface?


Please see the attached APDL macro. When run in Mechanical APDL, the Cap model yield surface will be displayed for the input parameters.

How to get deformed geometry of line bodies into ANSYS Mechanical?


FE Modeler cannot be used to create deformed geometry of Line Bodies, but FE Modeler can be used for creating deformed geometries of Surface and Solid Bodies<br><br>You can use APDL...

Configuring and Launching ANSYS CFX 14 - Distributed using Platform MPI


Please see the attached resolution document for a complete setup guide.

Configuring and Launching ANSYS FLUENT 14 - Distributed using Platform MPI or Intel MPI


Please see the attached resolution document for a complete setup guide.

CHEMKIN models fail in FLUENT R13.0 when run in parallel on Windows 7. Some linux versions may also be affected.

Errors such as these may occur:

OMP: Error #15: Initializing libiomp5md.dll, but found libguide40.dll already initialized.
OMP: Error #15: Initializing libiomp5md.dll, but found libguide40.dll already initialized.
OMP: Hint: This may cause performance degradation and correctness issues. Set environment variable KMP_DUPLICATE_LIB_OK=TRUE to ignore this problem and force the program to continue anyway. Please note that the use of KMP_DUPLICATE_LIB_OK is unsupported
and using it may cause undefined behavior. For more information, please see http://www.intel.com/software/products/support/.
OMP: Hint: This may cause performance degradation and correctness issues. Set environment variable KMP_DUPLICATE_LIB_OK=TRUE to ignore this problem and force the program to continue anyway. Please note that the use of KMP_DUPLICATE_LIB_OK is unsupported
and using it may cause undefined behavior. For more information, please see http://www.intel.com/software/products/support/.

999999 (..srcmpsystem.c@1173): mpt_read: failed: errno = 10054

999999: mpt_read: error: read failed trying to read 4 bytes: No such file or directory
MPI Application rank 0 exited before MPI_Finalize() with status 3
The Parallel FLUENT process could not be started.


New CHEMKIN installers are available for FLUENT 13.0 that will resolve these problems.<br><br>Go to <a target=_blank...

The following error occurs when launching CFX 14 in parallel:

mpirun_mpid version mismatch


From the ANSYS 14.0 Release Notes:<br><br>"CFX Distributed Parallel in ANSYS CFX 13 uses HP-MPI while CFX Distributed Parallel in ANSYS CFX 14 uses PCMPI. These different...

It seems that the Anisotropic elasticity sample, delivered under "General materials>Silicon Anisotropic" in WB v14 cannot be used.


This is a defect in R14.0. (Defect report CR03129) No material data is actually being saved to the mechdat file. The defect has been corrected for R14.5.<br><br>One workaround in R14...

How can I change the local in EKM for a Shared Advanced installation?


Follow these steps:<br><br>1. Stop the EKM server Service<br>2. Look in to the folder EKM_BASEprogramsjboss-5.1.0.GAserverekmwrapper and open the file...

The version of the license server 2325@servername [1.1.4 LM2] must be greater or equal to the client ANS_WB version [1.2.0].

Please update your license server to the latest version.


You are running ANSYS version R14.0, but your license server is still running R13.0.<br><br>Download the ANSYS License Manager from the ANSYS Customer Portal and install it in the same...

KNOWN ISSUE: Performing mesh modifications in CFX-Pre within Workbench may lead to problems when updating the Setup cell


SYMPTOM:<br>If any mesh modifications (such as renaming, glue/unglue, delete) or mesh transformations are performed on a mesh supplied to CFX-Pre by a Mesh cell in Workbench, and...

KNOWN ISSUE: Face ordering may change if Definition files are written from imported Results files


SYMPTOM:<br>Solver Input and Results files imported into CFX-Pre may not maintain mesh face set ordering when rewritten as a new Solver Input file. If results from the original file are...

KNOWN ISSUE: The CFX-Solver may not use the expected initial values when restarting a single fluid case from a case with multiple fluids


SYMPTOM:<br>When restarting a case with a single fluid from a case with multiple fluids, the initial values used for the single fluid in the restarted case may not be taken from the expected...

In WB-Mechanical, if you scope a convection load to a whole body, all the faces are convecting. What happens on surfaces that also have a thermal contact relationship and are in a closed condition? Is the convection deactivated at these locations?


No. When you define surface convection to the environment, WB-Mechanical meshes all these surfaces with SURF152 elements. At locations that have closed contact, convection heat transfer still...

How to setup Workbench 13.0 Remote Solve (RSM) from Windows 64-bit to Windows 64-bit Machines using the Remote Solve Manager


See attached Resolution Document.

Patch release, 14.0.8, addresses several limitations and defects reported since the release of Icepak 14.0. Specific defects corrected include


Readme<br><br>--------------------------------------------------------------------------------<br><br>Release 14.0.8 for Icepak Readme<br>This document provides...

In CFD-Post, the additional turbo-specific variable "Rotation Velocity" has always a positive sign, independent from the sign of Angular velocity or the rotation axis. Is this correct?


"Rotation Velocity" is a vector quantity written to the results file by the solver, it is not generated by CFD-Post and is independent of the additional components calculated by...

A patch has been release for Mechanical, 14.0.3, which addresses a defect related to running a Harmonic Response Analysis.


Readme<br><br>--------------------------------------------------------------------------------<br><br>Release 14.0.3 Readme<br>This document provides instructions for...

Icepak will not solve when running on the ANSYS, Inc. License Manager. Meshing works, but cannot solve. Error: Cannot find license file.

FLEXnet Licensing error:-1,359. System Error: 2 "No such file or directory"


These troubleshooting tips should help to resolve the issue of ANSYS Icepak not being able to solve.<br><br>Step 1: If it exists, remove the FLUENTLM_LICENSE_FILE environment...

When trying to load Workbench 14 you receive the error:

Failed to connect to remote job manager. The job manager "localhost" is an invalid name or has not been configured.


If you are not running on a MS Compute Cluster then the problem is that you cannot ping localhost. Release R14 is more sensitive to network issues.<br><br>Open a Command Prompt and...

POLYFLOW - What is the maximum number of boundaries (boundary sides) and sub-domains in POLYFLOW?


For far, for the convenience of menus, and for limiting the number of possible combinations, the limits are 30 sub-domains and 48 boundaries.

How can I perform multiple restarts and still save the current set of results within one project in WB R14?


After solving the first analysis system and saving the project,<br>duplicate the first system to a new system.<br>Open Mechanical in the new system, highlight the Solution Folder and...

When comparing element table reaction forces in ELBOW290 with those in PIPE289 and BEAM188 for identical model,
the table of reaction forces for elements 289 and 188 agree with each other but not with ELBOW290.
For ELBOW290, FX is reported as a constant value and this value appears to be an average of the variable list of numbers reported for 289 and 188.

Is this by design?


This is a defect (DE30176) in R14 that has been corrected for R14.5.

Configuring SSH (using Putty) to SSH to Linux Nodes (or cluster) from Windows for Fluent


Please see attached resolution document for a step by step tutorial.<br><br>Keywords: parallel, LSF, PBS, Linux

Installing and Configuring Native RSM to Use a Linux LSF or PBS Cluster and Running via Fluent or CFX from Windows


Please see resolution document for a step by step tutorial.

FLUENT 14 Local or Remote Job Submission using Windows to Windows