POLYFLOW - A field seems improperly initialised at the restart of a calculation


A non-isothermal transient calculation is restarted from an existing result file. When inspecting the sequence of result files, the temperature undergoes a jump, which suggests that the result file was not properly used. The temperature was previously initialised with a CSV file.
There may be a conflict of priority between the old result file and the CSV file. In order to circumvent this, we suggest removing the initialisation via the CSV file when a former result file is to be read.For information, the priorities are set as follows (in increasing sequence):
- initialisation with a constant value (item "average temperature")
- field read from an old result file OR an old CSV file
- initialisation from a CSV file (item "average temperature")





Show Form