Workbench runs correctly the first time, However each time thereafer, an Internet Explorer Script Error referencing StartScreen.htm occurs.

Dialog: Internet Explorer Script Error
Line 37
Char 2
URL: file: C:Program FilesAnsys IncAISOLStartPagestartPagesLanguageen-usStartScreen.htm
Do you wish to continue running scripts on this page?


This problem may be caused by Multi-byte/Unicode characters in the Windows username:
This has been observed when Korean characters are in the username:
Example : C:Documents and Settings???Application DataAnsysv81.

If you delete the ..v81 directory, Workbecch will again run correctly for the first time, then fail each time thereafer.

Workaround

The recommened workaround at this time is to change the username to standard characters
Example : C:Documents and SettingsjsmithApplication DataAnsysv81.


Note:
This error has been reported as Defect ID: 25858 - Workbench - Multi-byte/Unicode path name results in error when starting WB the second time