KNOWN ISSUE: The CFX-Solver may not use the expected initial values when restarting a single fluid case from a case with multiple fluids


SYMPTOM:
When restarting a case with a single fluid from a case with multiple fluids, the initial values used for the single fluid in the restarted case may not be taken from the expected fluid in the Initial Values file. The actual initial values used can be verified by writing a full transient or backup file before the iterations begin and inspecting the fluid values in CFD-Post. This limitation applies independent of whether or not the CFX Interpolator is used for the restart.

PROBLEM:
The CFX-Solver is not using the Fluid Definition names to match the fluids in the Initial Values file with the fluid specified in the Solver Input File.

WORKAROUND:
No workaround is currently available.

FIXED IN:
No fix is currently available.