QUESTION:



SFA is used to apply a heat flux to an area. The db is archived (cdwrite,all,test,cdb), the database is cleared, and the files are read back in (cdread,all,test,csb).

SFELIST shows the hflux properly applied. SFALIST indicates that a convection load was applied with a bulk temperature of a nearly infinite value (e31). The convection load is transferred to the elements during solve and the problem errors out during solution due to the tbulk.

Is this a bug?




ANSWER:

Yes, this is defect 19763, which was fixed at release 9.0


QUESTION:



SFA is used to apply a heat flux to an area. The db is archived (cdwrite,all,test,cdb), the database is cleared, and the files are read back in (cdread,all,test,csb).

SFELIST shows the hflux properly applied. SFALIST indicates that a convection load was applied with a bulk temperature of a nearly infinite value (e31). The convection load is transferred to the elements during solve and the problem errors out during solution due to the tbulk.

Is this a bug?




ANSWER:

Yes, this is defect 19763, which was fixed at release 9.0