Are there any examples of getting transmissibility factors in ANSYS Workbench?
Yes, please see the attached files for an ANSYS Workbench Simulation 9.0 example. A cantilever beam has its base displaced in a full harmonic response analysis. Frequency responses at three vertices are stored so that the accompanying command snippet can access displacement data for the corresponding nodes in POST26 (via the NSOL command). The POST26 command "QUOT" is used to divide the cantilever mid-span and tip displacements by the prescribed base motion to obtain the transmissibility factors. Please note the comments in the command snippets. **** Entered By: dciabatt @ 12/18/2006 07:34 PM **** The original Simulation 9.0 model does not run at 10.0, so a new model has been created and attached to this record (transmissibility_100.zip). |
||
|