Are there any examples of getting transmissibility factors in ANSYS Workbench?


Yes, please see the attached files for an ANSYS Workbench Simulation 9.0
example. A cantilever beam has its base displaced in a full harmonic
response analysis. Frequency responses at three vertices are stored so
that the accompanying command snippet can access displacement data
for the corresponding nodes in POST26 (via the NSOL command). The
POST26 command "QUOT" is used to divide the cantilever mid-span and
tip displacements by the prescribed base motion to obtain the transmissibility
factors. Please note the comments in the command snippets.

**** Entered By: dciabatt @ 12/18/2006 07:34 PM ****

The original Simulation 9.0 model does not run at 10.0, so a new model
has been created and attached to this record (transmissibility_100.zip).





Show Form