In ANSYS, Release 10.0, if morphing was previously activated in the MFS, it is necessary to explicitly deactivate it before writing a structural command file that pertains to elements with structural DOFs. Issuing the MORPH,ON command activates morphing. Once morphing is activated in the database, it remains active until it is explicitly deactivated by issuing the MORPH,OFF command. The MFCLEAR,SOLU command does not deactivated morphing. If morphing is active when a command file is written with the MFCM command, MORPH,ON will be written to that command file. Morphing cannot be applied to elements with structural DOFs, so if morphing was previously activated, it must be deactivated with MORPH,OFF before writing a command file that pertains to elements with structural DOFs.
|
|