Class 3 Error

SYMPTOM:
The Solver calculates incorrect source terms from particles to the continuous phase at partition boundaries, leading to overall sources that are too large. For example, the total mass source may be greater than the total mass flow rate of particles. Smoothing of particle vertex variables is similarly affected at partition boundaries.

PROBLEM:
This is due to a bug in the CFX Solver regarding communication of smoothing information between t


WORKAROUND:
The workaround for this is to run in serial mode, or to use the default non-smoothed sources.

FIXED IN:
Release 11.0. Custom executable for Release 10.0 available on request.