Class 3 Error

SYMPTOM:
If a compressible transient flow is undertaken with only one iteration per time step, then the solution can be incorrect if the Heat Transfer option is not set to Total Energy, or if heat transfer is not included in the simulation.

PROBLEM:
This is due to the Solver not extrapolating the pressure at the start of the time step in these circumstances. This means that density is not extrapolated, and so the code cannot calculate an accurate value for drho/dt on the fir


WORKAROUND:
Either run with at least two iterations per time step, or use the Total Energy option for Heat Transfer.

FIXED IN:
Not fixed yet.





Show Form
No comments yet. Be the first to add a comment!