How to modify single-layer SOLSH190 integration points?


In ANSYS Release 10.0, the number of integration points for SOLSH190 can be modified using the SECDATA and SECTYPE commands. You can associate a single-layered SOLSH190 element with a shell section. The SECDATA command requires you to specify a thickness. However, the specified thickness is not used for element calculations.