Why do FSUM,RSYS results in a cylindrical RSYS differ from FSUM results
when SPOINT is specified and the same cylindrical RSYS is active.


FSUM,RSYS transforms the individual nodal forces into the cylindrical
coordinate system before summing. FSUM with SPOINT sums the forces
in global cartesian and then transforms the sum.





Show Form
No comments yet. Be the first to add a comment!