Class 3 Error
SYMPTOM:
The wall shear stress for the solid phase of a fluidized bed modelled as a laminar flow is incorrect when using the kinetic theory model.
PROBLEM:
This is due to omission of the contribution to the stress from the solids shear and bulk
WORKAROUND: No workaround is currently available. FIXED IN: ANSYS CFX Release 12.0. |
||
|