Class 3 Error

SYMPTOM:
The wall shear stress for the solid phase of a fluidized bed modelled as a laminar flow is incorrect when using the kinetic theory model.

PROBLEM:
This is due to omission of the contribution to the stress from the solids shear and bulk


WORKAROUND:
No workaround is currently available.

FIXED IN:
ANSYS CFX Release 12.0.





Show Form