SYMPTOM:
When setting up a model in CFX-Pre with the External Coupling set to ANSYS Multifield or ANSYS Multifield via Prep7, the maximum number of iterations in a steady-state calculation is defaulted to 100, and the maximum number of coefficient loops in a transient case is defaulted to 10. Both of these numbers should have defaults of 3.

PROBLEM:
This is due to the default values specification not using information about the physical model.


WORKAROUND:
Change the values from their default values of 100 and 10.

FIXED IN:
ANSYS CFX Release 11.0 Update 1.