Class 3 Error

SYMPTOM:
An incorrect value may be used for the Specific Heat Capacity at Constant Volume.

PROBLEM:
An unset variable means that the solver may use an incorrect value for Specific Heat Capacity at Constant Volume.
(a) The Specific Heat Capacity at Constant Volume may be set to the same value as for the Specific Heat at Constant Pressure. This is correct for constant density materials, but not for others.
(b) In a multi-phase simulation, if the first fluid in the Fluids List is a constant density material, then the Specific Heat Capacity at Constant Volume may be incorrect for second and subse


WORKAROUND:
No workaround is currently available.

FIXED IN:
ANSYS CFX Release 11.0 Service Pack 1.





Show Form