Class 3 Error

SYMPTOM:
The quantity of an Additional Variable is monitored during a solver run using the integrated quantity function volumeInt(<var>)@Location. This value was compared with the result of the same expression in CFX Post. On 32bit systems, the values are comparable to within a small tolerance. However, the value is very different when evaluated in the 64 bit version of CFX-Post.

PROBLEM:
This is due to a bug


WORKAROUND:
No workaround is currently available.

FIXED IN:
ANSYS CFX Release 11.0 Service Pack 1.





Show Form
No comments yet. Be the first to add a comment!