SYMPTOM:
It is not possible to set a value for the Minimum Impact Angle which may be used at walls in particle transport calculations.
PROBLEM:
The units of Minimum Impact Angle are not set in the RULES file.
WORKAROUND: Edit the RULES file and add the missing units of [deg] to the default value and lower bound of the parameter 'Minimum Impact Angle'. FIXED IN: ANSYS CFX Release 12.0. |
||
|