Class 3 Error

SYMPTOM:
If data imported on a User Surface or Polyline is evaluated using an expression in a table, the function calculator or using macros, then the result may be incorrect. For example, if User Surface 1 is created and imports the data "p on User Surface 1", then evaluating "minVal(p on User Surface 1)@User Surface 1" may give an incorrect result. Note that plotting "p on User Surface 1" will still show the correct results.

PROBLEM:
If the data is not specified in SI units, then the units conversion is not handled correctly. Usually this wil


WORKAROUND:
Use SI units for the data in a Polyline or User Surface file.

FIXED IN:
ANSYS CFX Release 12.0.





Show Form