Why is the temperature non-uniform at a surface that convecting to a temperature-dependent Tbulk?
There is a bug in ANSYS 11.0 (72205) in the evaluation of Tbulk when the table is a function of temperature. It is using the hf evaluation temperature from the previous node in its evaluation, which is 1/2(Node Temp + Tbulk) by default. |
||
|