In Icepak model, how to view/modify assigned powers for components and how to find total power in a system?


The power value of a component can be viewed and modified using Power and temperature limits panel. The panel can be accessed via -
Model ---> Power and Temperature limits

The total power in the system is reported at the end of the table of this panel.

For additional information, refer following section:

Icepak 12.1 User Guide -> Power and Temperature Limit Setup-> Setting Up the Power and Temperature Limit Values





Show Form